getCITED   
  Home     Search     Add Content     Reports     Help  
Edit Publication | Edit Contributors | Delete Publication | Edit References | Edit Citations
Add to Bookstack | Show Bookstack | Change Bookstack

Rapid and mobile determination of alcoholic strength in wine, beer and spirits using a flow-through infrared sensor

Post a Comment
CONTRIBUTORS:
  Author Lachenmeier, Dirk W (Chemisches und Veterinaeruntersuchungsamt Karlsruhe)
  Author Godelmann, Rolf
  Author Steiner, Markus
  Author Ansay, Bob
  Author Weigel, Jürgen
  Author Krieg, Gunther
JOURNAL:
  Chemistry Central Journal, 4(??), 5 - ??.
YEAR: 2010
PUB TYPE: Journal Article
SUBJECT(S): alcohol, alcoholic strength, chemical analysis, infrared spectroscopy
DISCIPLINE: Chemistry
HTTP: http://www.journal.chemistrycentral.com/content/4/1/5
LANGUAGE: English
PUB ID: 103-470-220 (Last edited on 2010/03/23 05:50:47 GMT-6)
SPONSOR(S):
 
ABSTRACT:
Background Ever since Gay-Lussac's time, the alcoholic strength by volume (% vol) has been determined by using densimetric measurements. The typical reference procedure involves distillation followed by pycnometry, which is comparably labour-intensive and therefore expensive. At present, infrared (IR) spectroscopy in combination with multivariate regression is widely applied as a screening procedure, which allows one to determine alcoholic strength in less than 2 min without any sample preparation. The disadvantage is the relatively large investment for Fourier transform (FT) IR or near-IR instruments, and the need for matrix-dependent calibration. In this study, we apply a much simpler device consisting of a patented multiple-beam infrared sensor in combination with a flow-through cell for automated alcohol analysis, which is available in a portable version that allows for on-site measurements. Results During method validation, the precision of the infrared sensor was found to be equal to or better than densimetric or FTIR methods. For example, the average repeatability, as determined in 6 different wine samples, was 0.05% vol and the relative standard deviation was below 0.2%. Accuracy was ensured by analyzing 260 different alcoholic beverages in comparison to densimetric or FTIR results. The correlation was linear over the entire range from alcohol-free beers up to high-proof spirits, and the results were in substantial agreement (R=0.99981, p<0.0001, RMSE=0.279% vol). The applicability of the device was further proven for the analysis of wines during fermentation, and for the determination of unrecorded alcohol (i.e. non-commercial or illicit products). Conclusions The flow-through infrared device is much easier to handle than typical reference procedures, while time-consuming sample preparation steps such as distillation are not necessary. Therefore, the alcoholic strength can be economically and quickly controlled (requiring less than 60 s per sample). The device also gives the opportunity for mobile on-site control in the context of labelling control of wine, beer and spirits, the process monitoring of fermentations, or the evaluation of unrecorded alcohols.
STATISTICS
Click on # to view
 Citations  
 References   7 
 Comments  
 Quality      0/0.00 
 Interest      0/0.00 
 View(er)s   2/451 
Quality
  N/A
High
  7
  6
  5
  4
  3
  2
  1
Low
Interest
  N/A
High
  7
  6
  5
  4
  3
  2
  1
Low
Prev | Next

    ABOUT getCITED   |    CONTACT US   |    USER INFO   |    PREFERENCES   |    PRIVACY   |    LOG IN   
Comments? Suggestions? Send them to feedback@getCITED.org.

Copyright © 2000-2013 getCITED Inc. All Rights Reserved.