getCITED   
  Home     Search     Add Content     Reports     Help  
Edit Publication | Edit Contributors | Delete Publication | Edit References | Edit Citations
Add to Bookstack | Show Bookstack | Change Bookstack

Determination of cannabinoids in hemp food products by use of headspace solid-phase microextraction and gas chromatography-mass spectrometry

Post a Comment
CONTRIBUTORS:
  Author Lachenmeier, Dirk W (Chemisches und Veterinäruntersuchungsamt Karlsruhe)
  Author Kroener, Lars
  Author Musshoff, Frank
  Author Madea, Burkhard
JOURNAL:
  Analytical and Bioanalytical Chemistry , 378(1), 183 - 189.
YEAR: 2004
PUB TYPE: Journal Article
SUBJECT(S): Cannabinoids, Hemp food, Tetrahydrocannabinol (THC), Solid-phase microextraction (SPME), Gas chromatography (GC), Mass spectrometry (MS)
DISCIPLINE: Agricultural and Food Sciences
HTTP: http://www.springerlink.com/openurl.asp?genre=article&id=doi:10.1007/s00216-003-2268-4
LANGUAGE: English
PUB ID: 103-397-846 (Last edited on 2003/12/11 05:00:30 US/Mountain)
SPONSOR(S):
 
ABSTRACT:
A fully automated procedure using alkaline hydrolysis and headspace solid-phase microextraction (HS-SPME), followed by on-fiber derivatization and gas chromatographic–mass spectrometric (GC–MS) detection has been developed for determination of cannabinoids in hemp food samples. After addition of a deuterated internal standard, the sample was hydrolyzed with sodium hydroxide and submitted to direct HS-SPME. After absorption of analytes for on-fiber derivatization, the fiber was placed directly into the headspace of a second vial containing N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA), before GC–MS analysis. Linearity was good for D9-tetrahydrocannabinol (THC), cannabidiol, and cannabinol; regression coefficients were greater than 0.99. Depending on the characteristics of the matrix the detection limits obtained ranged between 0.01 and 0.17 mg kg–1 and the precision between 0.4 and 11.8%. In comparison with conventional liquid–liquid extraction this automated HS-SPME–GC–MS procedure is substantially faster. It is easy to perform, solvent-free, and sample quantities are minimal, yet it maintains the same sensitivity and reproducibility. The applicability was demonstrated by analysis of 30 hemp food samples. Cannabinoids were detected in all of the samples and it was possible to differentiate between drug-type and fiber-type Cannabis sativa L. In comparison with other studies relatively low THC concentrations between 0.01 and 15.53 mg kg–1 were determined.
STATISTICS
Click on # to view
 Citations   8 
 References   5 
 Comments  
 Quality      0/0.00 
 Interest      0/0.00 
 View(er)s   2/319 
Quality
  N/A
High
  7
  6
  5
  4
  3
  2
  1
Low
Interest
  N/A
High
  7
  6
  5
  4
  3
  2
  1
Low
Prev | Next

    ABOUT getCITED   |    CONTACT US   |    USER INFO   |    PREFERENCES   |    PRIVACY   |    LOG IN   
Comments? Suggestions? Send them to feedback@getCITED.org.

Copyright © 2000-2006 getCITED Inc. All Rights Reserved.