getCITED   
  Home     Search     Add Content     Reports     Help  
Edit Publication | Edit Contributors | Delete Publication | Edit References | Edit Citations
Add to Bookstack | Show Bookstack | Change Bookstack

Instrumentation of an ergometer to monitor the reliability of rowing performance

Post a Comment
CONTRIBUTORS:
  Author MacFarlane, D. J. (University of Hong Kong)
  Author Edmond, I. M.
  Author Walmsley, A.
JOURNAL:
  Journal of Sports Sciences (JSS), 15(2), ?? - ??.
YEAR: 1997
PUB TYPE: Journal Article
SUBJECT(S): ROWING; ROWING-ERGOMETRY; INSTRUMENTATION; ELITE-ATHLETE; MAN; MEASUREMENT; TEST-RELIABILITY; BIOMECHANICS
DISCIPLINE: No discipline assigned
HTTP:
LANGUAGE: English
PUB ID: 103-366-557 (Last edited on 2002/05/11 18:17:10 GMT-6)
SPONSOR(S):
 
ABSTRACT:
The aim of this study was to develop a portable data-acquisition system to measure the stroke-by-stroke power output and the force developed at the feet during simulated rowing, and to use the system to investigate the reliability of selected variables used to describe rowing performance. Using a Concept II rowing ergometer, the instantaneous power output was calculated as the product of the force at the handle, measured using a small transducer mounted near the handle, and the velocity of the handle, measured using an infra-red emitter-receiver to detect the passage of each vane of the flywheel. The cumulative force at the feet was measured using two force-plates, one mounted under each foot. The outputs from all transducers were sampled at 30 Hz using an 80386SX computer running Asyst data-acquisition software. Excellent linearity in all transducers was established and a calibration of the system revealed measurement errors of less than 3 percent. The reliability of the variables used to describe rowing performance was studied using a repeated 80 s maximal test on seven experienced oarsmen. Statistical analysis indicated that, of the 14 variables used, only two failed to meet the set criterion. In conclusion, it was found that a rower's performance during simulated rowing was very reliable and that the selected variables used in this study could be used to objectively describe performance on a rowing ergometer.
STATISTICS
Click on # to view
 Citations  
 References  
 Comments  
 Quality      0/0.00 
 Interest      0/0.00 
 View(er)s   2/302 
Quality
  N/A
High
  7
  6
  5
  4
  3
  2
  1
Low
Interest
  N/A
High
  7
  6
  5
  4
  3
  2
  1
Low
Prev | Next

    ABOUT getCITED   |    CONTACT US   |    USER INFO   |    PREFERENCES   |    PRIVACY   |    LOG IN   
Comments? Suggestions? Send them to feedback@getCITED.org.

Copyright © 2000-2006 getCITED Inc. All Rights Reserved.